Table 2. Comparison of the sensitivity of seven commercial master mixes for detecting porcine DNA by real-time PCR

Manufacturer Platform CT values for different concentrations of porcine DNA (ng/μL)
5×101 5×100 5×10–1 5×10–2 5×10–3 5×10–4
Applied Biosystems StepOnePlus 17.77±0.53 20.60±0.47 23.97±0.46 28.44±0.93 31.00±0.08 34.79±0.33
CFX Connect 17.38±0.23 20.01±0.18 24.65±0.04 27.92±0.32 32.15±0.04 ND
CancerROP StepOnePlus 18.54±0.09 20.56±0.12 25.44±0.47 29.18±0.48 32.09±0.72 ND
CFX Connect 15.72±0.44 18.23±0.64 22.54±0.52 26.52±0.02 29.91±0.17 33.41±0.52
Invitrogen StepOnePlus 17.01±0.16 19.79±0.34 23.71±0.21 26.91±0.22 30.86±0.30 33.78±0.21
CFX Connect 17.60±0.34 21.05±0.02 24.57±0.13 28.45±0.13 31.40±0.04 34.75±0.13
Kogene Biotech StepOnePlus 15.35±0.37 18.59±0.35 21.96±0.64 25.13±0.15 28.92±0.05 32.01±0.08
CFX Connect 17.40±0.45 20.55±0.42 23.97±0.41 27.20±0.03 30.75±0.12 33.81±0.43
New England Biolabs StepOnePlus 17.27±0.04 19.82±0.24 24.39±0.09 27.85±0.05 31.16±0.19 34.38±1.03
CFX Connect 17.61±0.11 19.11±0.69 22.38±0.34 25.89±0.48 29.65±0.54 32.56±0.16
Qiagen StepOnePlus 17.19±0.23 20.05±0.27 24.09±0.57 27.23±0.93 31.02±0.69 33.67±0.35
CFX Connect 17.08±0.26 20.81±0.06 22.81±0.13 26.62±0.32 30.36±0.45 33.36±0.17
Takara StepOnePlus 18.69±0.37 22.00±0.45 26.47±0.18 29.91±0.69 33.28±0.21 ND
CFX Connect 16.68±0.18 19.65±0.25 22.77±0.34 26.24±0.23 29.02±0.21 ND
Average CT values (mean±SD) for 50, 5, 0.5, 0.05, 0.005, and 0.0005 ng/μL porcine DNA analyzed in triplicate.
ND, not detected.